ALT98 Trouble Shooting |
Diagnostic Tester
The tester has built in self-diagnosis. There are three kinds of diagnosis
such as automatic diagnosis, manual diagnosis and terminal diagnosis.
How to read Diagnostic Report
Various numerical values are printed on the diagnostic result report. If
the meaning of the number is understood, it will turn out which portion
is out of order.
Encorder
The encoder mounted on the motor is amusing. You will look at at such time.
Special Mode
You will let an eye pass at once. It turns out that there is much special
function other than self-diagnosis in which it spoke about the point, such
as calibration and a memory display.
|
|
ALT98 Test Procedure |
The Test Procedure is the inspection method of a product. I want to consider whether the test method which is different in what method and order is created, and to see. In ALT98, the function inspected by the different test method for every product is added. For example, if leakage is taken for an example, in usual, leakage is seen only at once at the time of inspection starting. By changing the test method, it can also see at both of times of starting and an end. It also becomes the check of whether the problem has occurred in the situation of a regulator or a diode after load. Moreover, how about lengthening test time? More reliable inspection can be performed and it is.
The test method of CS-130
TestDelay 1250
TestLeakage 1250
Energize OFF
TestTOS INSPECTION
TestRegulator INSPECTION
TestIgnition
TestOutput FAST
END
How to make Test Procedure
It can customize by changing a command and a parameter.
|
|
ALT98 Statistics |
Setting up ALT98 and PC for collecting test result statictics
It is the history log of the product inspected with the tester. You will
take the log of which parameter or will customize personally.
Loading statistical report file.txt into the ALT98's flash memory
You can upload the setting file made personally from PC to a tester.
|
|
ALT98 Lable |
Print interpreter(IPRINT) is an software module built in ALT98 and ST10 tester. It allows a wide list of parameters to be printed in different formats and units. The basic idea is the customer is able to load in the tester description of the report and IPRINT interprets this report and inserts the actual test results into the data fields in a format specified in the description. This way statistical data, labels and reports can be customized in fast and easy way.
Printer Interpreter Command
You can make an original label.
|
|
ALT98 Attribute Map |
Map
It is ALT98 tester's site map.
|
|
ALT98 Upgrade |
After updating the firmware, why does Error #8 appear when runnig fast
diagnostic test ?
The tester has evolved.
Instructions for updating the ALT98 Firmware
|
|
Alternator Settings |
how to set alternator's settings (Delco,Ford,ND,Mitsubishi,Hitachi)
The knowledge about a product is required for creating product specification. A popular specification setup of a product is introduced
|
|
Network |
How to set up RS485 module to testers
A tester's network raises efficiency and management by leaps and bounds.
By connecting testers to network, the edited spec. is distributed to all
testers at once, or it is only at a certain specific tester. Moreover,
since statistics data is also sent to a server from each tester, it is
applied to unitary management of the shipment product in a factory. |