ST12 & ST24Trouble Shooting |
Solenoid Power Supply
A solenoid power supply is power supply equipment of 150A to a starter
S terminal. A control signal is outputted to a power supply from a measurement
board at the time of a test. It is confirmed whether the control signal
is outputted correctly. Caribration software is used for this check.
Starter Power Supply
A solenoid power supply is power supply equipment of 1500A to a starter
B terminal. A control signal is outputted to a power supply from a measurement
board at the time of a test. It is confirmed whether the control signal
is outputted correctly. Caribration software is used for this check.
"P" Error Trip on Servo Motor Driver
It solves by twisting the coil for absorbing trip current to a motor cable
as the measure method. The new model is shipped with a coil. since this
measure is not performed in an old model, please contact the visitor who
has not carried out yet
How to check Y3 board light status
It is one blink while the tester inclusion program is operating. Three
blinks are expressed while communicating with PC.
Out of Range RPM Error on ST12 or ST24
This is the problem of a parameter setup. It is the problem which occurs
in order to slow down from high number of rotations to low number of rotations
suddenly.
|
|
ST12 & ST24 Servo Drive Code |
Code list
It uses for diagnosis of a motor driver.
|
|
ST12 & ST24 Installation and Setup |
Installation and setup
|
|
ST12 & ST24 Battery Resistance |
Simple way to determine necessary battery resistance in stater testers
An output changes a lot with the setting value of battery resistance. It will be concerned also with reliance of the test itself if battery resistance of the product to inspect is not set up appropriately. It happens that a rated output attaches and runs the battery of very small capacity for a large product.
|